Designing, Building, and Flying
Wind Generators

Raising a wind machine and watching it produce power is an exhilharating experience. And if it does fly apart during a gale, the show is often worth the price of admission--plus you've obtained more knowledge for the next try!

First, figure out how big a wind generator you are willing to tackle, either commercial or home-brewed. There is really only one important measure of windmill size...the swept area. That's how many square feet (or meters, if you are into that sort of thing) of area the windmill's blades cover during a rotation.

The formula for swept area is Pi r2, where Pi is 3.1415 and r is the radius of your prop. The available power from the wind increases dramatically with the swept area...but so do the stresses on your blades, tower, bearings, tail. More stress means stronger engineering and materials are required, and a much larger, more complicated and expensive project. Windmills with props of 4 feet diameter and under are fairly easy to design, build and handle.

Once you get into the 7-8 foot range, everything must be very strong and rock-solid. At 10 feet and above, your materials and engineering need to be top-notch! Many people have learned this from the experience of watching windmills blow up, and we highly recommend building a smaller windmill like the 4-foot model in Hugh Piggott's Axial Flux Alternator Windmill Plans before trying a large windmill.

Here's some advice and ome observations about various aspects of designing, flying, building and destroying wind generators.

Site

Location--First, figure out the direction from which the prevailing winds in your area usually come. You can determine this by observation during wind storms, and by looking at the trees near your site. Trees that are all leaning the same direction and that have branches mostly on one side of the trunk are a good indication of prevailing wind speed and direction.

Local airports and weather stations can sometimes provide you with this information. A Logging anemometer that also records wind direction can be useful here, though expensive.

Height: Flying a wind generator close to the ground is like mounting solar panels in the shade! Your wind generator should be located at least 30 feet above any obstruction within 400 feet -- many sources recommend even more. Of course, this may be impractical, so just keep in mind that turbulance caused by obstructions will rob you of huge amounts of potential power, and cause extra stress on all components of your wind machine.

A higher tower is usually MUCH easier on your machine! At least make sure there are no obstructions between your windmill and the direction from which the wind usually blows. Remember that even an obstacle that's behind or to the side of your turbine in the prevailing wind will cause turbulance, rob you of power, and beat up your machine.

Distance: The distance between your wind generator and your batteries can also be a problem--the closer the better, to avoid losses in long wires and to keep the wire size required down to a reasonable thickness and cost. 12 volt systems are the worst for power transmission losses--you end up needing very thick wire. A 24v or 48v battery bank can save you big money on wire! Transformers can be used to keep the voltage high for long distances, but they cause added complexity and losses.

Tower

Your tower must be extremely sturdy, well-anchored, and tall enough to get above obstructions. 1.5 inch steel pipe can bend like a pipe cleaner in 50 mph winds, underneath a wind machine with only an 8-foot prop. Some wind energy guidelines tell you to plan on spending at LEAST as much on your tower and power wiring as on the wind generator itself!

Do you like to climb? The two basic kinds of tower are the Tilt-Up and Stationary. A stationary tower is the most sturdy and trouble-free, but you have to climb it to install, maintain or remove the wind machine. A crane is often used for installation, an expensive proposition--though you can do it yourself by climbing the tower and moving a gin pole up it as you add each new section. If climbing towers disagrees with you, go for a tilt-up. Then all maintenence can be performed while standing safely on solid ground.

Roof mount? We strongly recommend against mounting a wind generator on your roof. Though the manufacturer of the AIR 403 says it works, we have observed first-hand the vibration and noise during high winds in varous roof installations...it is VERY noticable and irritating. And keep in mind that the AIR 403 is a very small unit (only a 1.3 meter prop) that makes very little power...a larger mill would be unbearable, and possibly dangerous to your house itself.

Most commercial and homemade wind generators don't make much physical noise, but some vibration is unavoidable due to the nature of permanent magnet alternators.

Anemometers

It is essential to know the real windspeed in any wind generator installation, commercial or homemade. This allows you to see if the machine is performing correctly, and extremely high windspeeds might be a clue that you should shut the mill down for the duration of the storm. If you plan on investing significant money in wind power, a logging anemometer might help you decide if your local wind resource is worth the investment. Commercial anemometers and weather stations are very expensive, but can be found with a quick Google search...you can also try one of the homebrew options ******.

Generators and Alternators

We use the term Generator to describe a machine that produces Direct Current (DC), and use the term Alternator to describe a machine that produces Alternating Current (AC). However, the term Generator is also used generically to describe any machine that produces electricity when the shaft is spun.

Options
The alternator or generator is the heart of your wind machine, and it must be both properly sized to match your swept area, and produce the right type and voltage of power to match your application. Options include commercial and homemade permanent magnet (PM) alternators, PM converted induction motors, DC generators, DC brushless PM motors, vehicle alternators, and induction motors.

We cover the different types extensively on our Alternator and Generator Comparison page.

Application
Wind-generated electricity can be used for battery charging, heating, and for connection with the power grid. All of our designs and information are about battery charging, as we heat with wood and the nearest power line is 12 miles away from Otherpower.com headquarters.

Single Phase vs. Three Phase
3 phase offers some advantages over single phase in most alternators. Most small commercial wind turbines use 3 phase alternators, and then rectify the output to DC (direct current) for charging batteries. When building an alternator from scratch, single phase seems attractive because it is simple and easy to understand. 3 phase is not really any more difficult.

Going 3 phase allows for squeezing more power from a smaller alternator. It significantly reduces line loss, and it runs with less vibration. Older single phase alternators we made vibrate much more (and make more noise) than 3 phase machines.

Speed
The shaft speed is a very crucial factor in all types of alternator and generator. The unit needs to make higher voltages at lower rpms, otherwise it is not suited for wind power use. This goes for all power units...even motors used as generators and alternators should be rated for low rpms. This is also why vehicle alternators are not suited for wind power use, see our Alternator and Generator Comparison page for more details.

Start-Up Speed
This is the windspeed at which the rotor starts turning. It should spin smoothly and easily when you turn it by hand, and keep spinning for a few seconds. Designs that 'cog' from magnetic force or that use gears or pulleys to increase shaft speed will be poor at start up. A good design can start spinning in 5 mph winds and cut in at 7 mph.

Cut-In Speed
A wind generator does not start pushing power into the battery bank until the generator or alternator voltage gets higher than the battery bank voltage. Higher shaft speed means higher voltage in all generators and alternators, and you want to try and get the highest shaft speed possible in low winds--without sacrificing high-wind performance. Most commercial wind generators cut in at 8-12 mph. The generator's low-speed voltage performance, the design of the rotor (the blades and hub), and the wind behavior all factor into where cut-in will occur.

Voltage Regulation
With battery-charging windmills, voltage control is not generally needed--until the batteries fill up. Even if your alternator is producing an open-circuit voltage of 90 volts, the battery bank will hold the system voltage down to its own level. Once the betteries are full, you'll need to send the windmill's output to a 'dump load' such as a heating element. This regulation can be done manually by simple turning on an electric heater, stereo, or lights. Automatic systems can be built or purchased too.

Battery Bank Voltage
In addition to having less line loss, 24v and 48v power systems give other significant advantages in wind alternator systems. An alternator that cuts in at 300 rpm into a 12v battery bank will not cut in until 600 rpm into a 24v battery bank. However, the same machine may produce half again as much power at higher speeds into a 24v battery than into a 12v one. This is because of...

Efficiency
Every generator has a certain speed at which it runs most efficiently. But since the wind is not constant, we must try to design to a happy medium. As the wind speed rises, the raw power coming into the generator from the wind becomes more than the generator can effectively use, and it gets more and more inefficient. This power is wasted as heat in the stator coils.

Alternators with wound fields can adjust the magnetic flux inside to run most efficiently, but PM alternators cannot. An alternator that uses many windings of thin wire will have better low-speed performance than one that uses fewer windings of thicker wire, but higher internal resistance. This means it will become inefficient more quickly when producing higher amperage as wind speeds and power output rise.

The formula used to calculate power wasted from inefficiency is AMPS2 x RESISTANCE = Power wasted as heat in the alternator windings (in watts).

What does this mean in practice? Compare the performance of a Volvo Disk Brake Alternator to that of an Induction Motor PM Conversion Alternator.

The Volvo alternator internal resistance is 1/4 ohm, while the converted motor's resistance is 4 ohms.
The conversion alternator reaches 12 volts at very low rpms for cut-in, but look what happens at 10 amps of output: 400 watts being used as heat while charging the batteries at 130 watts.
With the Volvo alternator at 10 amps, only 25 watts are used up as heat, and at 50 amps it is wasting 625 watts while charging at 600 watts...and therefore is starting to become inefficient.

Alternator Design

Factors
Making PM alternators from scratch is sort of a "black art"--there are many factors that enter in to it, we try to discuss some of them below. And then, you must add in another important factor, the design of the blades. We discuss that below also. We didn't start building windmills and alternators by doing a bunch of math...we just jumped right in, made lots of mistakes, and eventually wound up with a satisfactory design by observing performance and changing one variable at a time!

Bearings
The operative word here is STRONG. Besides having to withstand vibration and high rotation speed, there is a significant amount of thrust back on the bearings from the wind, and it increases geometrically as the prop size increases. That's why using automobile wheel bearings is a good idea, they are tapered and designed to take the thrust loads.

The front bearings in converted AC induction motors are not designed for that kind of load. DC tape drive motors are especially vulnerable--the front bearing will eventually fail dramatically in high winds if extra bearings are not added.

Air Gap
This is the distance between the magnets and the laminates in a single magnet rotor design, or between two magnets in a dual magnet rotor design. The smaller the distance, the better the alternator performs. Halving the airgap gives 4 times as much magnetic flux. This means it's important to keep the coils as flat as possible, and to make the armature fit very precisely near the stator...if it is not perfectly square, the air gap will be larger on one side of the alternator than the other, and performance will be compromised.

Number of Poles
A 'pole' is either the North or South pole of a magnet. Generally when building an alternator we need a separate magnet for each pole. The faster that alternating north and south magnets poles pass the coils, the more voltage and current are produced.

But surface area is important as well. If we have a very narrow magnet (required for using many poles), the field strength would be much weaker over a distance than a wider magnet. So like all things with making wind turbines, there is a compromise to be made. We choose a number of poles that allows for reasonably sized coils and a good strong magnetic field through whatever airgap we wind up with. It must always be an even number.

If it's to be a single phase machine, we can have either the same number, or twice the number of poles as we do coils. If it's a 3 phase machine we like 4 poles for every 3 coils, although there are certainly other very feasable options. In most cases, for a 3 phase machine we'd have somewhere between 8 and 16 poles (magnets) unless perhaps the machine were to be very large.

Series or Parallel? Star or Delta?
When coils are connected in series, the voltage increases and so does resistance. When connected in parallel, voltage stays the same but amperage increases and resistance decreases. Also, parallel connections in an alternator can cause current to flow where you don't want it to, called 'parasitic losses.' The correct configuration for your project depends on many factors.

Magnets
The stronger, the better. The larger and stronger your magnets are, the more power you can produce in a smaller alternator. Neodymium-Iron-Boron ("rare earth", NdFeB) are by far the strongest permanent magnets known to man, and are ideal for building permanent magnet alterantors.

Many older designs call for strong ceramic magnets, this was mainly because of price. We do sell large, high-grade ceramic magnets that are suitable for alternator use, but in practice NdFeB magnets will give over 4 times as much power in the same space than ceramics. Plus, prices on large NdFeB magnets have dropped dramatically since they were first invented in the 1980s.

WARNING! Large NdFeB magnets are EXTREMELY powerful, and can cause serious injury. Read Magnet Safety Warnings before handling large magnets.

Wire
Enamelled magnet wire is always used for winding the stator, because the insulation is very thin and heat-resistant. This allows for more turns of wire per coil. It is very difficult to strip, use a razor knife or sandpaper, and be sure to strip each lead thoroughly!

Choosing the gauge of wire is yet another trade off--thinner gauge wire allows for more turns per coil and thus better voltage for low-speed cut-in, but using longer, thinner wire gives higher resistance and therefore the unit becomes inefficient faster at high speeds. Larger alternators use 10-16 gauge wire, the smaller ones 18-22 gauge.

Magnetic Circuit
Picture a magnet to be almost like a battery. The lines of force from a magnet are said to originate at one pole and return to the other, just like a battery. Air is a poor conductor, both for electricy and for magnetic lines of force.

In order to make best use of a magnet (and copper wire) in an alternator, we need to have the strongest possible magnetic field. Just like copper is a good conductor of electricity, steel is a good conductor of magnetic fields. A good magnetic circuit involves steel between the poles with a gap (the airgap) where we need to utilize the field.

In an alternator, the wires should occupy the airgap, it should be no wider than necessary, and every other part of the magnetic circuit should be of steel. We can either use steel laminates (laminated steel reduces eddy currents) or we can have magnets on each side of the coil(s) moving together with steel behind them. Again, look at our various wind turbine experiments to see. It should be said that some of them, like the wooden alternator and the all wooden windmill have very poor magnetic circuits.

 

Rotor

A wind generator gets its power from slowing down the wind. The blades slow it down, and the alternator collects the power. BOTH must be correctly designed to work together and do this efficiently. We are not experts at blade design...we sort of started in the middle with a functioning design, and made changes from there.

Really, you could make a simple set of blades with a straight 5 degree pitch down the entire length and they would work JUST FINE! But to really tune in the performance of your wind generator, it's important to pay attention to a few factors.

Some REALLY GOOD rotor design information can be found on Hugh Piggott's Website. Another excellent resource is WindStuffNow.com, with good information and low cost blade design software.

Blade Material
Wood is really an ideal material for blades. It is very strong for its weight, easy to carve, inexpensive, and is resistant to fatigue cracking. Choose the best, straightest, most knot-free lumber you can find; pine and spruce are excellent. Hardwoods are generally too heavy.

Steel and aluminum blades are much too heavy and prone to fatigue cracking; sheet metal would be a poor choice, and extremely dangerous.

Cast reinforced glassfibre blades are very strong, and are common on commercial windmills, but the mouldmaking process would take longer than carving a complete set of blades from wood, and there would be little or no gain in strength.

Diameter
Blades that are too short attached to a large alternator will not be able to get it moving fast enough to make good power. Blades that are too large for a small alternator will overpower and burn it up, or overspeed to the point of destruction in high winds, there's not enough of an alternator available to collect the energy coming in from the wind.

Number of Blades
The ideal wind generator has an infinite number of infinitely thin blades. In the real world, more blades give more torque, but slower speed, and most alternators need fairly good speed to cut in.

2 bladed designs are very fast (and therefore perform very well) and easy to build, but can suffer from a chattering phenomenon while yawing due to imbalanced forces on the blades.

3 bladed designs are very common and are usually a very good choice, but are harder to build than 2-bladed designs. Going to more than 3 blades results in many complications, such as material strength problems with very thin blades. Even one-bladed designs with a counterweight are possible.

Tip Speed Ratio (TSR)
This number defines how much faster than the windspeed the tips of your blades are designed to travel. Your blades will perform best at this speed, but will actually work well over a range of speeds. The ideal tip speed ratio depends on rotor diameter, blade width, blade pitch, RPM needed by the alternator, and wind speed.

Higher TSRs are better for alternators and generators that require high rpms--but the windspeed characteristics at your particular site will make a big difference also. If in doubt, start in the middle and change your blade design depending on measured performance.

Taper
Generally, wind generator blades are wider at the base and narrower at the tips, since the area swept by the inner portion of blades is relatively small. The taper also adds strength to the blade root where stress is highest, gives an added boost in startup from the wider root, and is slightly more efficient.

The ideal taper can be calculated, and it varies depending on the number of blades and the tip speed ratio desired. Hugh Piggott's Windpower Workshop book and his free Blade Design Notes contain the relevant formulas, and WindStuffNow.com's blade design software will help you with this too.

Honestly, though...if you simply take a look at a picture of a functioning small-scale wind generator's blades and estimate the taper by the eyeball method, you will come very close to meeting the criteria and have a very functional blade. The calculation is done by balancing the thrust from lift with the energy needed for Betz's momentum change and Newton's Laws.....!

Pitch and Twist
A simple wind generator blade with a straight 5 degree pitch down the whole length would give adequate performance. There are advantages to having a twist, though--like with taper, having more pitch at the blade root improves startup and efficiency, and less pitch at the tips improves high-speed performance.

The wind hits different parts of the moving blade 's leading edge at different angles, hence designing in some twist. One of the common blade designs that's right in the middle for design parameters is to build an even twist of 10 degrees at the root and 5 degrees at the tip--but the ideal solution will also depend on your alternator cut-in speed, efficiency and local wind patterns.

Carving
Layout and carving process is very simple...after marking the cut depth at the trailing edge at both the root and tip, the two depths are connected with a pencil line. Use a hand saw to make layout cuts into the blade every couple inches along the length before firing up the electric planer...when the saw kerfs disappear, the pitch is correct.

Airfoil
There are great lengths that you can go to for designing an airfoil...NASA has some great information and calculations out there on the net. But all an airfoil needs to do is maximize lift and minimize drag. Find a likely looking airfoil cross section from a working wind generator blade, and copy it. A power planer makes quick work of carving it, and a drawknife is great for carving too, especially with the deep cuts near the blade root.

Balancing
The blades must be very well balanced to prevent vibration. This is more easily accomplished with a 2-blade rotor than a 3 bladed one. But generally, simply use a homemade spring scale to make sure that each blade weighs exactly the same, and that each has the same center of balance. A simple balancing jig for any rotor configuration can be made with an upright spike that sticks into a dimple punched at the exact center of the hub. Excess material from the heavy areas can be removed quickly with a power planer. You'll also need to balance the blade in place on the alternator. It's weight distribution can be adjusted by attaching lead strips to the blade root.

Furling and Shutdown Systems

Furling Systems
The term "furling system" is used to describe a mechanism that turns the wind generator rotor at an angle out of the wind, either horizontally or vertically, to protect the machine from damage during high winds. Ideally it will keep power output levels near the maximum even when fully furled. Our early wind turbine designs didn't use furling systems, and we feel fortunate that some of them are still flying. A wind turbine that furls is also much more gentle on your tower and guy wires--the force on an overspeeding wind turbine increases as the wind gets stringer..

There are a variety of furling system designs:

Variable Pitch
An ideal but extremely complicated solution is to use blades which change pitch depending on the wind speed....these also have the advantage of keeping power output at the most efficient point for the current windspeed. During low winds, the blades are pitched for best startup. In higher winds, they rotate and adjust shaft speed to the ideal RPMs for the generator.

In extreme winds, they turn the blades even further to protect the unit from damage. The problem is the complexity of making a system work reliably...but it can be done! Large commercial wind generators use this system exclusively, as do antique and modern Jacobs turbines, and some old WinChargers.

Tilt-Back
In these designs, the generator body is hinged just behind the nacelle. When wind speed gets too high, the entire nacelle, hub and blade assembly tilts back out of the wind to nearly vertical. As the wind slows down, it returns to normal horizontal operating position by either springs, wind action on a tilted tail, or a counterweight. Commerical wind generators that use this method are the old Whisper models (from before the buyout), the Windstream, and many homemade designs.

Furling Tail
The generator is mounted off-center horizontallly from the yaw bearing. The tail is also angled in this axis. The tail is also angled in the vertical axis, and hinged. When the wind force back on the rotor is strong enough to overcome the off-axis generator making it want to yaw and the angled tail trying to keep it from yawing, the tail folds up and turns the alternator away from the wind direction, forcing the wind turbine to yaw out of the wind. When wind speeds drops, the tail is returned to normal operating position by gravity, or springs. Many commercial and homemade designs use this system, and it has proven to be very reliable.

Folding Vane
Similar to the furling tail, but the tail boom is fixed, with a hinged vane underneath. Used on some older Winchargers and homemade designs, the disadvantage is that tail and vane are more highly stressed from wind force during furling, as they still are sticking out there in the gale.

Flexible Blades
The theory is that the blades flex both back toward the tower and around their main axis, and therefore protect themselves from overspeeding. It does work if the materials and details are correct...for example, the blades must not flex back far enough to hit the pole, and they must withstand flexing during cold weather too.

The popular Air 403 and new Air X from SouthWest Windpower use this system for furling. One problem is that it is noisy....in fact the Air 403 is noisy even in gentle 15 mph winds, BEFORE it starts producing power and in hihg winds can sound like a primeval monster howling. The Air X has some fancy electronic circuitry to reduce noise.

Air Brakes
Noisy and full of vibration, but they do work. Older WinChargers used this system. Metal cups extend from the hub from centripetal force during high winds, and noisily slow the machine down; they retract back into the hub when the wind slows.

Shutdown Systems

This is a manual control that completely shuts the wind generator down. It is not allowed to spin at all, and should be able to survive extremely violent winds in this condition. It can be electrical or mechanical.

Electrical Shutdown
With permanent magnet alternator machines, simply shorting the main AC power output leads together should effectively shut down the wind turbine. In theory, when the machine is spinning at high RPMs during a windstorm, the shutdown may be either impossible electrically (the turbine is performing too inefficiently for shorting the output to have any effect), or too damaging to the alternator (the heat produced in the stator coils by shutdown at high speeds turns the coils into molten slag.)

One normal method is to simply wait for a space between high wind gusts to short the mill with a switch. Shutdowns at 10-30 amps of output (into 12v) generally cause no problems. You can use a manual switch, or simply a shorting plug to do this.

Homebrew designs should never have problems with refusing to stop in high winds when shorted.

Mechanical Shutdown
These systems physically brake the wind generator, or force it out of the wind by turning the tail parallel to the blades. Even the mighty Bergey Excel 10kW wind turbine has a mechanical crank for emergency shutdown. Generally, a cable is attached to a hinged tail, with a small hand winch located at the bottom of the tower for the operator.

Regulation

With battery-charging wind generators, regulation of the incoming voltage is accomplished by the battery bank itself, until it is fully charged. Though a PM alternator or DC generator's open-circuit voltage might be 100 volts, the battery bank keeps the wind generator circuit voltage at its own level.

Once the battery bank fills, system voltage will rise rapidly and something must be done with the uneeded incoming power. Simply disconnecting the windmill is not an option--a windmill allowed to 'freewheel' will quickly blow itself up from overspeed. The power must be diverted into some sort of load.

Turn on Some Lights!
This is the oldest, simplest and most reliable method of regulation. Problem is, you have to be there to do it. But by turning on house lights, heaters, etc. that more or less equal the extra power coming in, you prevent the batteries from overcharging, keep a load on the windmill and keep your system voltage in the normal range.

Shunt Regulation
These systems simply sense the battery voltage and divert all or part of the incoming wind power into heating elements (known as a 'dump load'), thus keeping a load on the windmill while ceasing to charge the batteries.

The very simplest solution is a manually thrown switch that disconnects the incoming power from the batteries and connects it to some heating elements...just keep in mind the voltage requirements of the heaters must be a good match to the alternator for braking to occur.

Simple systems that divert all the incoming power at once can be built using Trace C-series charge controllers or relays and voltage sensors. More complicated systems use power transistors or pulse width modulation to divert only part of the incoming power, or the entire amount, as charging needs require.

Both Home Power Magazine and Hugh Piggott's Website have plans and schematics for building shunt regulators. Some commercial solar charge controllers can be set to function as dump load controllers, like the Trace C40. A controller intended only for solar power will NOT function with a wind turbine, nor will an automotive voltage regulator.

Diodes
A permanent magnet DC generator (such as a surplus tape drive motor) does need a diode in the line--otherwise, the battery bank will simply spin it as a motor. The diode should be rated for higher amperage than the maximum output of the motor, and must be well heat-sinked.

Bridge Rectifiers
Since alternators make AC power and batteries need to charge with DC power, conversion is needed. This is accomplished with bridge rectifiers, which are simply an array of diodes. For single-phase alternators, standard bridges with 4 diodes are used. The biggest bridge that's commonly available at a reasonable cost is 35 amps--for larger wind generators multiple 35 amp bridges can be hooked in parallel to give greater power handling capacity.

The bridges must be well heat-sinked to a large piece of finned aluminum or steel. Three-phase alternators need rectifiers that use 6 diodes in an array...these can be scavenged from old car alternators, or built using 6 large barrel diodes.

Slip Rings

The power produced by the generator must be transferred down the tower to your power system. Since the actual wind generator must yaw to keep pointed into the wind, the main power wires must be able to handle this. There are 2 options...

Pendant Cable
It is much easier to simply use a length of flexible cable and a steel safety cable instead of slip rings. Use the highest quality stranded, flexible cable you can find and attach it in a loose loop from the wind generator power terminals to where your feed wire comes up the pole. Use a length of wire that allows about 3 or 4 wraps around the pole. Or, run the wire down the center of the tower pipe and let it twist inside.

Experience has shown that while the cord can eventually wind itself around the pole, it will also eventually unwind itself. Some models have flown for years with this kind of system and required no maintenance. With a properly designed wind turbine and furling system, you should hardly ever see the mill make a 360 degree yaw. Simply use a power plug and socket at the bottom of the tower and unplug it once or twice a year to untwist the wire. We've seen commercial turbines on 120 foot towers that successfully use the pendant cable system.

Make or Convert Slip Rings
Slip rings can be salvaged from old car alternators and converted to wind generator use, or built from scratch using copper pipe, PVC pipe and graphite brushes. Home Power Magazine has had articles in the past about both methods. We have never felt the need to use them and they make for another potential failure point, so we have not experimented with it.